The accident occurred during a refinery turnaround on 17 September 2025. According to the account of Havindustritilsynet’s (Havtil) investigation, a hook snagged on a remaining bolt, causing a heat exchanger weighing about 7.5 tonnes to move unexpectedly. A rigger was trapped between two heat exchangers and died shortly afterwards.
Havtil identified the snagged hook as the immediate cause, alongside wider failings. The regulator found that lessons from earlier incidents had not been adequately incorporated into working practices and that known safety concerns had received insufficient follow-up.
At Equinor, the findings covered the management and planning of lifting work, materials handling, operational leadership and radio communications. The three non-conformities at Crane Norway Vest concerned competence, the provision of information and the execution of lifting operations.
According to Havtil, Equinor had also failed to ensure that hired personnel had the additional competence required for rigging and signalling. NRK reported that the workers checked by the regulator, including the man who died, did not meet the contract’s requirement for one year of relevant experience.
A crane operator also halted a lifting operation on the day of the accident because they considered the situation unsafe. Havtil concluded that the measures taken were inadequate.